TS-DIM
Installation Guide
Franklin Fueling Systems • 3760 Marsh Rd. • Madison, WI 53718 USA
Tel:  +1 608 838 8786 • 800 225 9787 • Fax: +1 608 838 6433 • www.franklinfueling.com
Manual # Revision Date Changes from Previous Revision
000-2044 B Aug. 2012 Added Cabling and Programming information
Vue de la page 0
1 2 3 4 5 6 ... 29 30

Résumé du contenu

Page 1 - Installation Guide

TS-DIMInstallation Guide Franklin Fueling Systems • 3760 Marsh Rd. • Madison, WI 53718 USATel:  +1 608 838 8786 • 800 225 9787 • Fax: +1 608 838 6433 

Page 2 - Abbreviations and Acronyms

10TS-DIM/G to Gilbarco DBox Universal/TS10000TS-DIM/G Adapter Cable(P/N 600-0202 for current loop)(P/N 600-0201 for RS422)Gilbarco Consoleto Controlle

Page 3 - Contents

11TS-DIM/G Adapter Cable (P/N 600-0201) TS-DIM/G TS-DIM/G Console to Controller Connector (P/N 601-1004) DB9 to RJ45 Adapters Gilbarco Dbox PA03060020

Page 4 - Important Safety Messages

12Gilbarco G-SITE Controller C2 Style TS-DIM/GS RJ45 to DB9 Adapter (P/N 601-1002) RJ45 to DB25 Adapter (P/N 601-1001) Note: If the 600-0205 cable i

Page 5 - System Installation

13Pump Specic Installation — TS-DIM / W for Wayne / Dresser Electronic DispenserFollowing the instructions in the TS-DIM General Installation section

Page 6 - Diagnostic Port

14Wayne/Dresser DBoxTS-DIM/WTS-DIM Wayne/Dresser Adapter Cable(P/N 600-0203)Note: See the Wayne/Dresser DBox TS-DIM/W Connection Example Diagram belo

Page 7 - TS-DIM Power Requirements

15Wayne Fusion DIM Connection1.  Setup the Fusion as described in the “Fusion Installation – HyperPIB-PAM-Console” manual. See step A Below.2.  Reboot

Page 8 - TS-DIM Dimensions

16Pump Specic Installation — TS-DIM / T for Tokheim Electronic DispenserFollow the instructions in the TS-DIM General Installation section, and then 

Page 9 - Pump Specic Installation

17Smart Fuel Controller ConnectionFollow directions below to connect the INCON console to VeriFone’s Smart Fuel Controller (SFC). Using this interface

Page 10 - Figure 7

18Dispensers 1-8 Dispensers 9-16Dispensers 9-16SFC Aux BoardSFC DistributionBoardModified TSP-GDCBL CableDo NOT cut white wireOrange wireFigure 15: Mo

Page 11 - Figure 8

19DIM DiagnosticsExtensive testing and data collection is available to the user through the TS-DIM’s built-in diagnostic port, which is physically loc

Page 12 - Figure 10

2PrefaceThis manual contains instructions for the installation of the INCON TS-DIM (Dispenser Interface Module), which monitors transactions between d

Page 13 - Wire Color Function

20 Accessing the Internal DiagnosticsThe database section of the diagnostics will show the transaction totals for each fueling position. 1.  At the DI

Page 14 - Figure 12

21Clearing the Database Using Privileged ModeNormally, at startup, the totals for all pumps are zero, but, in some situations, the Fueling Positions m

Page 15 - Wayne Fusion DIM Connection

22Using the Internal Diagnostics to Collect Site DataBe prepared, some of these steps involve dispensing at least 1/10 of a gallon of each product fro

Page 16 - Figure 13

23Acquiring and Saving Wayne Dispenser Line FactorsThe following instructions are only applicable for the TS-DIM installations in which the Wayne/Dres

Page 17 - Current Loop Wire

24Programming the Tank GaugeNO. METERS:  The total number of all Fueling Point Meters at the site. This is located under the SYSTEM menu. A value abov

Page 18 - Modified TSP-GDCBL Cable

25TroubleshootingTroubleshooting Electronic VersionsTable 1 TS-DIM – Diagnostics – Electronic DispensersProblem Recommendation / AnalysisTS-DIM do

Page 19 - DIM Diagnostics

26Table 3 Gilbarco MOC G-SITEProblem Recommendation / AnalysisNo data capture. • Is the EMC port on G-SITE enabled?• Is the correct software versi

Page 20 - Denitions

27TS-DIM Installation on a T5 Series Console Some sites and dispenser congurations may require the use of a second DIM module that would be installed

Page 21 - (not shown)

28Wiring the TS-DIM to a T5 Series ConsoleTurn off the main power source/all power sources that terminate in the console before working on or servicin

Page 22

29In the programming, you cannot exceed the number of fueling points under DIM 1. Put in the max number of fueling points under DIM 1, the other fueli

Page 23

3ContentsPreface... 2Abbrev

Page 24 - Programming the Tank Gauge

30©2012 INCON 000-2044 Rev. B3760 Marsh Road ● Madison, WI 53718 U.S.A.Tel: +1 608 838 8786 ● Fax: +1 608 838 6433 ● www.franklinfueling.comTel: USA &

Page 25 - Troubleshooting

4Important Safety MessagesINCON equipment is designed to be installed in association with volatile hydrocarbon liquids such as gasoline and diesel fue

Page 26 - General Technical Information

5Description of TS-DIM ComponentsThe TS-DIM collects information on all dispensed product and consolidates the data to a concise, easy-to-read format,

Page 27

6TS-DIM General Installation Steps – For Electronic Dispensers1.  A junction box with a single receptacle outlet must be provided (see the TS-DIM Powe

Page 28 - Figure 23: Enable RS-485

7TS-DIM Power RequirementsThe TS-DIM must be powered from a dedicated 115 VAC single circuit breaker, with no other devices connected to the power rec

Page 29 - Figure 24: DIM 2 Setup

8TS-DIM General Installation Steps – Wiring the TS-DIMWiring the TS-DIM to a Dbox and Power Receptacle1.   With all of the power off, install and wire

Page 30 - Figure 20

9Pump Specic InstallationTS-DIM / G for Gilbarco Electronic DispenserGilbarco MOC (Major Oil Company) G-SITE Systems are specially congured. For Gil